1. PR interval: defined from beginning of P wave to the beginning of the QRS complex. Corresponds to the time taken for the impulse to travel from the SA node to the ventricles. Normal: 0.12-0.20 sec.
2. QRS complex: represents ventricular depolarization. Upper limit: 0.12 sec.
3. QT interval: defined from the start of the QRS complex to the end of the T wave. Represents the time from the onset of ventricular depolarization to full repolarization. HR dependent.
4. QTc interval: QT interval that has been corrected for variations in HR (standardised to 60 beats/min) & and permits comparison between and within individuals. Normal: 0.35-0.43 sec.